1, MPGD tracker updates by Sourav (Vanderbilt University):

Sourav compared the central tracking performance in |eta|<1. Compared the tracking performance between micro-Rwell and micromegas. The current technology choice for the ECCE gas tracker is micro-Rwell and micromegas is treated as a backup. Sourav also compared the tracking performance with different detector configurations and will cross check the configuration.

2, ECCE tracking performance updates by Xuan (LANL):

Xuan compared the tracking performance between the 1st simulation and 2nd simulation production. The tracking momentum and DCA_2D resolutions are compared for different detector configurations: general tracking, silicon tracking and inner tracking. DCA_2D resolutions are comparable with different detector configurations. For tracking momentum resolution in the central region, general tracking < inner tracking < silicon tracking due to the different level arm (R) coverage in the central region.

The current tracking momentum resolutions are evaluated with displaced vertex on, it's better to turn this flag off and evaluate the tracking momentum resolution.

 

3, Updates on ECCE Tracker AI WG by Cristiano (MIT), Karthik (Univ. of Regina):

Karthik and Critiano provide the tracking performance evaluation for general tracking from the 2nd simulation production. They also presented the working in progress updates on the optimized detector geometry and reshaping the service parts. Improvements in the 1<|eta|<1.5 region have been achieved, which are most tracking service parts located. Will report further updates in upcoming meetings.